Differences
This shows you the differences between two versions of the page.
— | f:flint_laboratory [2021/09/03 12:47] (current) – created - external edit 127.0.0.1 | ||
---|---|---|---|
Line 1: | Line 1: | ||
+ | ======Flint Laboratory====== | ||
+ | |||
+ | **Constructed**: | ||
+ | |||
+ | **Architects**: | ||
+ | ---- | ||
+ | |||
+ | ===== Design and construction ===== | ||
+ | < | ||
+ | <a href=" | ||
+ | <br /><a href=" | ||
+ | <br /><a href=" | ||
+ | <br /><a href=" | ||
+ | <br /><a href=" | ||
+ | </ | ||
+ | |||
+ | |||
+ | Flint Laboratory is located southwest of Stockbridge Hall at the end of Campus Center Way. The building’s site slopes gradually down to the west towards Chenoweth. Primary access the building is provided by a set of concrete stairs on the east side of the building that connect to a bituminous concrete walkway. There are light poles along the sidewalk. On the south side of the building, the bituminous concrete walk transitions to a concrete walk. Between the sidewalk and building vegetation includes evergreen shrubs in a mulched bed. On the east side of the building landscaping is currently under construction, | ||
+ | |||
+ | Flint Laboratory is a 2-story Georgian Revival brick structure with a hip roof, an entry portico, and hip roof dormers on its south elevation. The building is three bays wide and nine bays deep, with a slate roof, stone trim and a brick foundation. The trim includes a water table, stringcourses, | ||
+ | |||
+ | The main entry is in the east elevation at the top of a six-step stone stairway, within an entryway that has Roman Doric columns. The door is a double-leaf door that has 2/3 panes in each leaf’s upper half and a single panel its lower half. The doorway has a blind fanlight above it, and a high-relief carving of a cow’s head in the keystone above the fanlight. A set of paired 6/6 /8 windows is set above the doorway. The entry portico is flanked by small and narrow 3/1 windows, with a large 10/10 window at the north side of this small window. Here and elsewhere on the east and south elevation, some of the 10/10 windows have been modified to accommodate the installation of window air conditioner units. The balancing 10/10 window on the south side of the entry has been removed and the window opening has been blocked with brick. The east elevation’s second story has a 10/10 window on either side of the central paired windows. | ||
+ | |||
+ | Reading from west to east, the south elevation’s first story historically was comprised of three 10/10 windows; a double-leaf door with 3/3 panes in the upper half of each leaf, and a transom above the door; a single 10/10 window; another double-leaf door with a transom; and three more 10/10 windows. The window at the west end of this elevation has been removed and blocked with brick. A small door has been installed in the lower part of the former window opening. The south elevation’s second story contains nine 10/10 windows. The attic has two hip roof dormers. Each dormer contains a triple window that is comprised of a central 3/2 window that is flanked by 1/1 windows. | ||
+ | |||
+ | All the first story windows have stone lintels with keystones. The corners of the building are decorated with a brick corner pilaster and the bays on the east and south elevations are separated by pilasters. | ||
+ | |||
+ | =====1867-1916: | ||
+ | In the absence of a coordinated plan, the Trustees put existing buildings that were acquired with the campus land into service as agricultural laboratories. Campus development for several decades after 1863 was sporadic and focused on the construction of individual buildings to meet specific functional needs of the fledgling university. It was not until after 1900, during a period of rapid student population growth and resultant new building construction, | ||
+ | |||
+ | In 1912, a professional landscaping publication reported that Warren H. Manning, formerly affiliated with the Olmsted firm, had spent over four years preparing a comprehensive plan for the University Trustees. The Trustees had considered it imperative for the college to plan harmonious development that would conserve the beauty of campus grounds while meeting the needs of a growing student population whose expanding range of activities was unprecedented. | ||
+ | |||
+ | Manning’s plan designated three distinct sections of the campus, the Upland, Midland and Lowland Sections. Each section was intended to be the locus of specific functions, with clusters of purpose-built structures to serve those functions. For example, one section would be designated for faculty, women’s and horticultural facilities. A second section would contain administration, | ||
+ | |||
+ | Although Manning’s Upland, Midland, and Lowland sections are not fully realized, it is apparent that discipline specific groupings were developed. Building clusters, especially those related to agriculture, | ||
+ | |||
+ | =====1910-1920=== | ||
+ | By World War I and continuing through the 1920s, University records frequently refer to the inadequacy of the physical plant; the lack of class room space; the lack of properly ventilated and lighted spaces; and the danger of having to cancel classes because of a lack of appropriate facilities. Expansion of the campus through acquisition of additional land was considered essential if the University were to construct new and better facilities to address these deficiencies and excel as an institution of higher education. | ||
+ | |||
+ | |||
+ | =====Flint Laboratory=== | ||
+ | This structure was built as a dairy laboratory and is named for Charles L. Flint, fourth President of the Massachusetts Agricultural College. He also served as member and Secretary of the first Board of Trustees of MAC. More information about Charles Flint may be found in Frank Prentice Rand’s // | ||
+ | |||
+ | |||
+ | =====Landscape Analysis=== | ||
+ | West Experiment Station, East Experiment Station, Draper Hall, Flint Laboratory, Stockbridge Hall, and Goessman Laboratory were constructed between 1885 and 1922 along the north side of Olmsted Road. Although oriented in an irregular pattern today, historically, | ||
+ | |||
+ | To the southwest of the complex were Flint Road (now Campus Center Way) and a ravine that ran to the south of what is now Campus Center Way, draining the Campus Pond. The area to the southeast of the complex was historically open lawn leading to the Campus Pond with a few scattered deciduous trees and desire-line paths. A pedestrian walk led through the open lawn, connecting Draper Hall to the intersection of the cross-campus walk and North Pleasant Street. This walk is no longer extant, obstructed by the construction of the [[c: | ||
+ | |||
+ | Flint Laboratory and [[s: | ||
+ | |||
+ | |||
+ | ===== Naming of the building ===== | ||
+ | |||
+ | Named in honor of Charles L. Flint, President of the Massachusetts Agricultural College, 1879-1880. | ||
+ | |||
+ | ---- | ||
+ | |||
+ | ==== Source ==== | ||
+ | * From the Massachusetts Historical Commission, UMass Amherst [[http:// | ||
+ | * A newspaper article on the construction of the building in the [[http:// | ||
+ | * See also the [[http:// | ||